
{"id":749,"date":"2019-06-24T12:18:53","date_gmt":"2019-06-24T12:18:53","guid":{"rendered":"https:\/\/budker.uni-mainz.de\/?p=749"},"modified":"2022-12-12T13:27:46","modified_gmt":"2022-12-12T13:27:46","slug":"nv-centers-for-eddy-currents-imaging-zulf-magnetometry-and-3d-magnetic-field","status":"publish","type":"post","link":"https:\/\/budker.uni-mainz.de\/?p=749","title":{"rendered":"NV centers for eddy-currents imaging, ZULF magnetometry, and 3D magnetic field"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">We use nitrogen-vacancy (NV) centers in diamond to produce pictures based on the magnetic fields created by eddy-currents [<a href=\"https:\/\/journals.aps.org\/prapplied\/abstract\/10.1103\/PhysRevApplied.11.014060\">1<\/a>]. Such an approach enables to discriminate different materials according to their conductivity. Our device has a bandwidth of 3.5 MHz and a spatial resolution of 0.3 mm.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"489\" src=\"https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-2-1024x489.png\" alt=\"\" class=\"wp-image-750\" srcset=\"https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-2-1024x489.png 1024w, https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-2-300x143.png 300w, https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-2-768x367.png 768w, https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-2.png 1321w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption> From [<a href=\"https:\/\/journals.aps.org\/prapplied\/abstract\/10.1103\/PhysRevApplied.11.014060\">1<\/a>], the symbol of the city of Mainz. In the middle (b) &#8211; a photograph of the symbol. (a) and (c) are eddy-current imaging by NV of the phase (in a) and amplitude (in c) of the magnetic field from eddy current. <\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Then, we use NV centers as the magnetic field sensors at zero- and ultra-low magnetic field (ZULF) [<a href=\"https:\/\/arxiv.org\/abs\/1811.11498\">2<\/a>]. We refer to ZULF as the magnetic field&#8217;s range where the spin dynamics in a molecule is dominated by j-couplings (instead of the Zeeman effect). Then, Larmor frequency is much smaller than j-coupling frequency. NV centers are not used in ZULF often due to technical limitations which we overcome using frequency-modulated, circularly polarized microwaves. The use of such microwaves enables us to selectively drive resolved hyperfine transitions in NV centers.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"579\" height=\"578\" src=\"https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-3.png\" alt=\"\" class=\"wp-image-751\" srcset=\"https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-3.png 579w, https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-3-150x150.png 150w, https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-3-300x300.png 300w\" sizes=\"auto, (max-width: 579px) 100vw, 579px\" \/><figcaption> From [<a href=\"https:\/\/arxiv.org\/abs\/1811.11498\">2<\/a>], relative frequencies of transitions in NV centers as a function of the magnetic field acting on them. Labeled are the transitions matching NV centers, which are oriented along the direction of the applied magnetic field. The black dashed lines are the result of computer simulation.\u00a0 The color scale indicates in percent the peak depth of the corresponding spectrum line, relative to the off-resonant case. <\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">In a recent project, we took NV centers but, as opposed to [<a href=\"https:\/\/arxiv.org\/abs\/1811.11498\">2<\/a>], and similarly to [<a href=\"https:\/\/journals.aps.org\/prapplied\/abstract\/10.1103\/PhysRevApplied.11.014060\">1<\/a>], we did not use microwaves this time. Instead, we relied on ground state level anticrossing (GSLAC) in the triplet ground state (at 102.4 mT) to measure simultaneously all three spatial components of the magnetic field [<a href=\"https:\/\/arxiv.org\/abs\/1904.04361\">3<\/a>]. The benefit of GSLAC is that we have a sharp magnetic resonance (as a function of applied magnetic field) without microwaves. Thus, we obtained a 3D picture of the probed magnetic field!<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" width=\"473\" height=\"537\" src=\"https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-4.png\" alt=\"\" class=\"wp-image-752\" srcset=\"https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-4.png 473w, https:\/\/budker.uni-mainz.de\/wp-content\/uploads\/2019\/06\/image-4-264x300.png 264w\" sizes=\"auto, (max-width: 473px) 100vw, 473px\" \/><figcaption> From [<a href=\"https:\/\/arxiv.org\/abs\/1904.04361\">3<\/a>], measurements (in red) of the magnetic fields in three directions, as a function of the parameter describing the total applied (in green) magnetic field $ B = \u00a0\u00a0\\left\\{ A cos(2 \\pi t) , B sin (2  \\pi  t) , 6.82 t\u22123.41 \\right\\} $ where   $ A = B = \\sqrt{ R^2 &#8211; B z^2} $ .<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">References:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[1]\nEddy-current imaging with nitrogen-vacancy centers in diamond,&nbsp;Georgios\nChatzidrosos, Arne Wickenbrock, Lykourgos Bougas, Huijie Zheng, Oleg Tretiak,\nYu Yang, and Dmitry Budker,<a href=\"https:\/\/journals.aps.org\/prapplied\/abstract\/10.1103\/PhysRevApplied.11.014060\" target=\"_blank\" rel=\"noreferrer noopener\">&nbsp;Phys. Rev. Applied 11, 014060<\/a>&nbsp;(2019).&nbsp; &nbsp;<a href=\"https:\/\/arxiv.org\/abs\/1810.02723\" target=\"_blank\" rel=\"noreferrer noopener\">arXiv:1810.02723<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[2]&nbsp;Zero-field\nmagnetometry based on nitrogen-vacancy ensembles in diamond,&nbsp;Huijie Zheng,\nJingyan Xu, Geoffrey Iwata, Till Lenz, Julia Michl, Boris Yavkin, Kazuo\nNakamura, Hitoshi Sumiya, Takeshi Ohshima, Junichi Isoya, Joerg Wrachtrup, Arne\nWickenbrock, Dmitry Budker,&nbsp;<a href=\"https:\/\/arxiv.org\/abs\/1811.11498\" target=\"_blank\" rel=\"noreferrer noopener\">arXiv: 1811.11498<\/a>&nbsp;(2018).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">[3]\nMicrowave-free vector magnetometry with nitrogen-vacancy centers along a single\naxis in diamond, Huijie Zheng, Zhiyin Sun, Georgios Chatzidrosos, Chen Zhang,\nKazuo Nakamura, Hitoshi Sumiya, Takeshi Ohshima, Junichi Isoya, J\u00f6rg Wrachtrup,\nArne Wickenbrock, Dmitry Budker,<a href=\"https:\/\/arxiv.org\/abs\/1904.04361\" target=\"_blank\" rel=\"noreferrer noopener\">&nbsp;arXiv:1904.04361<\/a>&nbsp;(2019).<\/p>\n","protected":false},"excerpt":{"rendered":"<p>We use nitrogen-vacancy (NV) centers in diamond to produce pictures based on the magnetic fields created by eddy-currents [1]. Such an approach enables to discriminate different materials according to their conductivity. Our device has a bandwidth of 3.5 MHz and a spatial resolution of 0.3 mm. Then, we use NV centers as the magnetic field [&hellip;]<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":"","_links_to":"","_links_to_target":""},"categories":[1],"tags":[],"class_list":["post-749","post","type-post","status-publish","format-standard","hentry","category-default"],"_links":{"self":[{"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=\/wp\/v2\/posts\/749","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=749"}],"version-history":[{"count":16,"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=\/wp\/v2\/posts\/749\/revisions"}],"predecessor-version":[{"id":768,"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=\/wp\/v2\/posts\/749\/revisions\/768"}],"wp:attachment":[{"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=749"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=749"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/budker.uni-mainz.de\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=749"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}